Quick answer

Fit a brush or hinged-flap excluder to the bottom of each external door, foam or brush strips around door and window frames, a brush or flap on the letterbox, a disc cover on the keyhole, strips around the loft hatch, and a removable excluder in any unused chimney. The Energy Saving Trust puts the saving at around £55 a year for windows, floors and doors and another £45 for an open chimney in Great Britain. Never seal trickle vents, air bricks, extractor fans or the ventilation a gas or solid-fuel appliance needs.

A draught is heat you have already paid for leaving through a gap. In a normal winter it shows up as a bill. In a cold snap with the boiler down or the power off, it decides how fast a house loses the warmth it has. Either way, sealing the gaps is the cheapest heating job in the house, and most of it is a Saturday morning with a screwdriver.

The catch is that a house needs to breathe. Seal the wrong hole and you trade a draught for damp, or starve a gas appliance of the air it needs. This guide goes gap by gap: what to fit, what it saves, and the short list of things you must leave alone.

What the figures say

The Energy Saving Trust gives two savings estimates for a typical home. Draught proofing around windows, floors and doors saves around £55 a year in Great Britain and £80 in Northern Ireland. Fitting a draught excluder to an open chimney you do not use saves around another £45 a year in Great Britain and £60 in Northern Ireland. The Trust does not state a house type or fuel for these figures, so treat them as a central estimate.

Add them up and a typical home with an unused chimney is losing about £100 a year through gaps it could close for good:

Measure Saving per year (GB) Saving per year (NI)
Windows, floors and doors £55 £80
Unused open chimney £45 £60
Both £100 £140

The 2016 government factsheet quoted a lower £25 to £35 a year for windows and doors in a three-bedroom semi with a family of four, using the Trust’s April 2016 costs. That estimate is a decade old; use the Trust’s current figure.

There is a second gain the figures miss. A room with no moving cold air feels warmer at the same temperature. The Trust puts the saving from turning a thermostat down from 22°C to 21°C at £120 a year in Great Britain, and a draught-free room is the one where you can do that without noticing.

The payback arithmetic

As of November 2026 the Trust says having a professional draught proof the windows and doors of a whole house could cost around £250. Divide cost by saving:

  • Professional, £250 ÷ £55 a year = about 4.5 years to pay back.
  • Do it yourself with, say, £40 of strips and brushes: £40 ÷ £55 = under a year. Put your own receipt total in place of £40.
  • Chimney excluder on an unused flue, at whatever it costs you: divide by £45 and you have the payback in years.

Little else in the heat pillar pays back that quickly for so small an outlay.

Gap by gap: what to fit

External doors

The Trust lists four places on a door. Work through all four.

  1. The gap at the bottom. Fit a brush strip or a hinged-flap excluder along the inside foot of the door. The brush rides over an uneven threshold; the flap lifts as the door opens.
  2. The letterbox. A letterbox brush or a flap. Measure the opening first, because sizes vary.
  3. The keyhole. A purpose-made cover that drops a metal disc over the keyhole of a mortice lock.
  4. The edges. Foam, brush or wiper strips around the frame, as for a window.

Do not draught proof internal doors. They need the gap underneath so air can move around the house. The one exception, from the government factsheet, is a door between a heated room and an unheated one, such as a porch or a cold hallway, where a sausage-shaped fabric excluder on the floor does the job and lifts away when you want it to.

Windows

For windows that open, you have two choices of strip around the frame. Self-adhesive foam is cheap and quick but may not last long. Metal or plastic carriers with a brush or rubber wiper cost a little more and last longer. Whichever you pick, the strip has to fill the gap: too thick and it is crushed or the window will not close; too thin and the draught sails past it. Measure the gap with a coin or a folded card before you buy.

Sliding sash windows are the exception. Foam strips do not work well on them. Fit brush pile strips along the sash edges, or ask a joiner.

Windows that never open want silicone sealant around the frame, not a strip.

Loft hatch

Treat the hatch like a door: draught strip around the frame, and insulate the hatch itself, because a bare hatch is a cold square in a warm ceiling. Where pipes rise into the loft above an airing cupboard, fill around them with silicone, wall filler or expanding foam.

Chimney

An unused chimney is a hole the size of a dinner plate open to the sky. The Trust gives two fixes: a cap on the chimney pot, usually terracotta, which also keeps rain and birds out and, as of November 2026, starts at around £150; or a chimney draught excluder fitted inside the flue or around the fireplace opening, which you can do yourself.

Two rules. The Trust says the excluder must not fully block the flue. And you take it out before anyone lights a fire. If the fireplace is used, or a stove or gas fire vents through that flue, do not fit one at all.

Floors, skirting and pipes

Gaps between floorboards and along the skirting take a flexible filler: silicone, decorator’s caulk or a mastic that tolerates movement. Wipe off the excess with a damp cloth before it sets, because it is permanent. Small gaps where pipes pass through an outside wall take silicone; large ones take expanding polyurethane foam.

Cracks in walls and ceilings take a hard-setting filler. A large crack is a question for a surveyor before it is a job for filler.

What you must never block

This is the part that matters more than any product. The Energy Saving Trust is blunt: good ventilation is essential, and you should not block vents, chimneys or any airflow needed for safety and air quality. Specifically:

  • Trickle vents above windows. Leave them open all the time.
  • Air bricks and wall vents. They keep wooden joists and floors dry.
  • Extractor fans in kitchens, bathrooms and utility rooms. They cannot be draught proofed. Only an empty outlet where a fan has been removed can be sealed, and the Trust says to ask a professional if unsure.
  • Fixed ventilation for gas appliances. You must not block ventilation openings that serve flueless or open-flue gas heaters, and take care in a room with a gas hob.
  • Rooms with an open fire or open flue. Do not seal their draughts.

Every one of those vents is there to carry moisture out and, where there is a flame, to carry combustion air in. Seal them and the best case is condensation and mould; the worst is carbon monoxide. If you heat with gas, oil, wood or coal, check your carbon monoxide alarm is in the right place before you start sealing anything.

One more check. If your home has no trickle vents, no wall vents and no extractor fans, the Trust says it may already be too airtight, and more draught proofing may not suit it. Older homes with traditional features are harder to get right; the Trust’s advice is to use a professional, and to get three quotes.

Why this belongs in a resilience plan

A draught-proofed house is a slower-cooling house. When the heating stops, whether that is a boiler fault, a frozen condensate pipe or a long power cut, the gaps you sealed in October are what keep the one warm room warm in February. The plan for keeping warm without heating starts with shrinking the house to one room and blocking its draughts; this guide is how you do the blocking in advance, properly, instead of with a rolled towel on the night.

Draught proofing is also the first rung of the permanent fix. Seal the gaps, then insulate the loft, then look at the walls and the glazing. Each step makes the heat you generate, by whatever means, last longer. The heat pillar walks through that order, and the planner will tell you how much heat your household needs to cover for the number of days you choose.

What to do today

  1. On the next windy day, go round every external door, window, the letterbox, keyhole, loft hatch and fireplace with the back of your hand, and write down each gap.
  2. Measure each gap and each letterbox before you order anything. The wrong size does nothing.
  3. Fit the door bottoms and letterbox first. They are the biggest gaps and the quickest wins.
  4. Find every trickle vent, air brick and extractor fan in the house and make sure none of them is painted over, stuffed or covered. Leave them that way.
  5. If a chimney is unused, fit a removable excluder and write “chimney blocked” on a note by the hearth so nobody lights a fire under it.

Equipment mentioned

Brush strip for the bottom of an external door
Screws to the inside face of the door; the brush rides over the threshold.
See options
Self-adhesive foam draught strip
For casement windows and door frames; match the thickness to the gap.
See options
Brush pile strip for sash windows
Foam fails on sliding sashes; brush pile is the right fit.
See options
Letterbox brush and flap
Measure the letterbox opening before you order.
See options
Keyhole cover
A disc that drops over the keyhole on a mortice lock.
See options
Removable chimney draught excluder
Unused chimneys only. Take it out before any fire is lit.
See options

Links go to Amazon.co.uk search results; we earn a commission if you buy. How we earn.

Make it specific to your household. The planner turns the figures in this guide into litres, kilocalories and watt-hours for your people and your home, in about five minutes. Free, no sign-up.

Questions people ask

Do draught excluders actually work?

Yes, within limits. The Energy Saving Trust estimates draught proofing windows, floors and doors saves around £55 a year in Great Britain and £80 in Northern Ireland, with another £45 (GB) or £60 (NI) for an unused open chimney. The bigger gain is comfort: a room without moving cold air feels warmer at the same thermostat setting.

Should I draught proof internal doors?

No. The Energy Saving Trust says internal doors need the gap underneath for air to move around the house. The exception is a door between a heated room and an unheated one, such as a hallway or porch, where the government factsheet suggests a simple fabric excluder along the bottom.

Which is better, foam strip or brush strip?

Self-adhesive foam is cheaper and quicker to fit but does not last as long. Metal or plastic carriers with a brush or rubber wiper cost more and last longer. Foam does not work well on sliding sash windows, where brush strips on the sash edges are the right fit.

Can I block up a chimney I never use?

Fit a removable chimney draught excluder or have a cap put on the pot, but do not seal the flue completely: the Energy Saving Trust says an excluder should not fully block the chimney. Take the excluder out before you light a fire, and never fit one in a chimney that serves a working stove, open fire or gas fire.

Will draught proofing cause damp or condensation?

It can if you seal the ventilation the house relies on. Keep trickle vents open, leave air bricks and extractor fans alone, and do not block vents in rooms with a gas hob, flueless heater, open flue or open fire. If your home has none of these vents, the Energy Saving Trust says it may already be too airtight for more draught proofing.

How do I find the draughts in the first place?

Wait for a windy day, close the external doors and windows, and run the back of your hand slowly around door edges, window frames, the letterbox, keyhole, skirting, floorboards, pipe entries and the fireplace. Moving curtains, whistling and daylight showing under a door all mark a gap.

Sources: Energy Saving Trust: Draught proofing, Energy Saving Trust: How to draught proof your windows and doors, Department of Energy and Climate Change factsheet: Draught proofing (PDF)

This guide is general information for UK households, not advice for your specific circumstances. In a live emergency follow the instructions of the emergency services, your utility and your council.