UPS for a router: how to keep your broadband on when the power goes off
A UK broadband router draws about 7–13 watts and a full-fibre box (ONT) another 3–5, so a mini UPS needs roughly 12 Wh of battery for every hour you want online, or 18 Wh an hour for router plus ONT. A £40 mini UPS rated 18 Wh gives about an hour; the 56 Wh units providers sell give three to five; a 250 Wh portable power station gives fourteen or more. Beyond the first hour or so, your connection also depends on the network's own batteries, which are not guaranteed.
The router is the quietest essential in the house. When the power fails it takes the Wi-Fi, the digital landline, the smart meter display, the doorbell camera and, for anyone working from home, the working day with it. The analogue phone network is being retired, with the switch to digital due to finish by January 2027 according to the government’s guidance, so a landline now runs through the router too, and a power cut means no phone unless a mobile has signal.
The fix is small and cheap compared with most of the communications pillar. A router is a 10-watt device. A battery the size of a paperback keeps it running for hours. The hard part is knowing which battery, and understanding that your end is only half of the chain.
What a router actually draws
ISPreview measured the main UK providers’ routers in March 2024. Idle figures ran from about 6.5 W (Vodafone’s Wi-Fi Hub) to 13.5 W (Virgin Media’s Hub 5), with BT and Sky hubs at 7–10 W. Under load the same boxes drew 10.6–15.5 W. The article estimates a full-fibre ONT, the small box the fibre enters, at a further 3–5 W for gigabit-class units.
For planning, use these round figures:
| Set-up | Typical draw | Wh needed per hour (÷ 0.85) |
|---|---|---|
| Router only (FTTC, cable) | 10 W | 12 Wh |
| Router plus full-fibre ONT | 15 W | 18 Wh |
| Router, ONT and a cordless phone base | 18 W | 21 Wh |
The 0.85 allows for the loss in converting battery power to the voltage the router wants. Treat the result as a ceiling rather than a promise.
The sizing sum
Watt-hours needed = watts × hours ÷ 0.85.
- A 10 W router for four hours: 10 × 4 ÷ 0.85 = 47 Wh.
- Router and ONT, 15 W, for four hours: 15 × 4 ÷ 0.85 = 71 Wh.
- Router and ONT for a working day of eight hours: 15 × 8 ÷ 0.85 = 141 Wh.
Run the sum the other way to see what a given battery buys you. Hours = Wh × 0.85 ÷ watts.
Watch the units when you shop. Many listings quote milliamp-hours, which only mean something alongside a voltage. A unit built from four 2,600 mAh cells is sold as “10,400 mAh”, which sounds large, but the same listing rates it at 18 Wh. To convert a cell figure yourself, multiply mAh by 3.7 (the cell voltage) and divide by 1,000: 10,400 × 3.7 ÷ 1,000 = 38 Wh in the cells, of which the maker promises 18 Wh at the output. The Wh figure is the one that counts.
Your options, with the arithmetic
| Option | Energy | Router only (10 W) | Router + ONT (15 W) | Price seen, November 2026 |
|---|---|---|---|---|
| Mini UPS, four 18650 cells | 18 Wh rated | about 1.5 h | about 1 h | around £38 |
| Provider battery backup unit (Vodafone/Wire design) | 56 Wh | about 4.8 h | about 3.2 h | £150, or free if landline-dependent |
| Portable power station, small | 250 Wh | about 21 h | about 14 h | see the sizing guide |
| Portable power station, 1 kWh | 1,000 Wh | about 85 h | about 57 h | see the sizing guide |
A mini UPS is a battery pack with a mains adapter in, and 5 V USB, 9 V and 12 V barrel outputs. It sits between the wall and the router, charges itself, and switches to battery when the mains drops, which is the whole point of a UPS. Typical four-cell units are rated at 18–24 W total output and about 18 Wh of storage. Check three things before buying: that the output voltage matches the label on your router’s adapter exactly, that the barrel plug fits (most come with a bag of adapters), and that the unit ships with a UK mains lead rather than a two-pin European one. The listing fetched for this guide had an EU plug.
A provider unit does the same job with more battery and a tested design. The government’s resilience guidance says such a unit can power a router for several hours, typically four to seven. Vodafone’s unit, built with Wire Technologies and also offered through BT, KCOM and Zen, holds 56 Wh, powers the router and ONT together, and keeps 25 per cent of its charge back for emergency calls. Vodafone quotes four to seven hours; the sum above says about three to five once a real router and ONT are drawing from it. BT’s earlier unit was designed around Ofcom’s minimum of at least one hour and sold for £85 in 2024; its BBU Plus is designed to run for four hours and then drop to an idle mode that reserves power for a 999 call. ISPreview reported in January 2026 on one unit that failed in two cuts out of three, with the model and cut lengths unknown: a fair reminder to test whatever you buy.
A portable power station is the long-cut answer and the one that also charges phones and runs lights. Plug the router’s own adapter into the station’s mains socket. The portable power station guide does the sizing for the whole household; a router and ONT all day is about 140 Wh of the budget.
The half you do not control
A battery at home keeps your equipment alive. It does not keep the network alive, and here the picture is honest but uneven.
Fibre carries no power from the exchange, and a router needs mains whatever kind of line it sits on. The street cabinet, the exchange and the mobile mast all need their own batteries or generators too. Ofcom’s resilience guidance of September 2024, as ISPreview reported it, expects core network sites to survive power loss for at least five days. For the active street cabinets that serve FTTC broadband, Ofcom considered a four-hour requirement, decided the retrofit cost was too high, and instead recommended around four hours as good practice for new installations. In 2022, ISPs told ISPreview off the record that backup at the edge of their networks commonly lasted four to eleven hours, and that mobile networks were often among the first to fail.
For mobile masts there is still no minimum. Ofcom floated one hour of battery at every mast in 2024, put the cost at £0.9–1.8 billion, and judged it not proportionate for now. Ofcom also told a 2023 Freedom of Information request that it does not record mast backup durations.
The practical reading: in a local cut of an hour or two, a battery on your router will very likely keep you online. In a cut that stretches past four hours, or one that takes out a whole district, expect the connection to drop whatever you have at home. Plan for the first case; do not bet the household on the second.
If you depend on your landline
Ofcom’s guidance under General Condition A3.2(b) requires providers to offer at least one way of reaching emergency organisations for a minimum of one hour in a power cut at the premises, free of charge, to customers who depend on their landline. Ofcom’s examples are people with disabilities or accessibility needs, and people with no mobile or no reliable mobile coverage at home. The solution can be a battery backup unit or, where coverage is adequate, a mobile handset. Your provider does not know you qualify until you tell them. The landline switch-off guide covers what to say and what to plug in.
Set it up so it works on the night
- Read the labels. Note the voltage, amps and plug type on the router adapter and, if you have one, the ONT adapter. The ONT is usually a separate small box near where the fibre comes in.
- Size for the cut you expect. Four hours is a sensible target: about 47 Wh for a router-only home, about 70 Wh for router plus ONT.
- Put the battery between the wall and the router, and the ONT if the unit has a second output, then pull the plug and time how long you stay online. A test on a quiet evening tells you more than any spec sheet.
- Swap the cordless phone base for a corded handset in the router’s phone port. A cordless base needs its own mains and will not run on the router’s backup.
- Keep the phones charged and know which rooms get mobile signal, so you have a second route when the network side fails. The power cut checklist has the 105 number and the rest of the routine.
The permanent fix
A mini UPS is the quick answer. The durable one is a home battery that the router simply lives on: a portable power station kept topped up, or a solar-and-battery system with a backup circuit that keeps the router, lights and fridge running on their own. After that, the open question is how long the cabinet down the road lasts, and the only answer you control is a charged phone and a known patch of mobile signal. The planner budgets the router at 40 Wh a day alongside the rest of the household’s loads for the number of days you choose.
What to do today
- Find the router and ONT adapters and photograph their labels.
- Work out your hourly Wh: 12 for a router, 18 for router plus ONT.
- If anyone in the house depends on the landline, ring the provider and ask for the free battery backup.
- Otherwise order a mini UPS with a UK lead and at least 18 Wh, or earmark part of a portable power station.
- When it arrives, pull the plug and time it.
Equipment mentioned
| Mini UPS for a router, 12 V Look for the Wh figure, not the mAh. Check it has outputs matching your router's and ONT's voltages and plugs, and that it comes with a UK mains lead. | See options |
| Portable power station, 250–300 Wh Runs router and ONT for half a day and charges phones too. Plug the router's own adapter into its mains socket. | See options |
| Corded telephone Draws its power from the router's phone port, so it keeps working on backup where a cordless base will not. | See options |
Links go to Amazon.co.uk search results; we earn a commission if you buy. How we earn.
Make it specific to your household. The planner turns the figures in this guide into litres, kilocalories and watt-hours for your people and your home, in about five minutes. Free, no sign-up.
Questions people ask
Does broadband work in a power cut?
Not unless something is powering your router, and your fibre box if you have one. Fibre cannot carry electricity the way an old copper line did, so everything at your end stops when the mains does. With a battery backup on the router, the connection usually keeps working for as long as the network's own backup lasts.
What size UPS do I need for a router?
Multiply the router's watts by the hours you want, then divide by 0.85 for conversion losses. A 10 W router for four hours needs about 47 Wh; add a fibre ONT at 5 W and the same four hours needs about 71 Wh. Most mini UPS units are rated 18–56 Wh, so expect one to five hours rather than a whole day.
Will a mini UPS power my full-fibre ONT as well as the router?
Only if it has enough output sockets at the right voltages and enough capacity. Many cheap units have one 12 V and one 9 V barrel output plus USB, which can feed a router and an ONT together, but the run time halves. Check both power supplies for their voltage and plug size before buying.
Can I get a free battery backup from my broadband provider?
If you depend on your landline, because you have no mobile or no mobile signal at home, Ofcom requires your provider to offer free of charge a way to reach the emergency services for at least one hour in a power cut, often a battery backup unit. Other customers can buy one from the provider or a retailer.
Will the mobile network work when the power is off?
Sometimes. Ofcom has not set a minimum battery backup for mobile masts, and when it looked at the question in 2024 it judged a one-hour requirement too costly for now. Masts near you may stay up for a while or fail quickly. Keep phones charged and treat mobile data as a second route, not a certainty.
Is a portable power station better than a mini UPS?
For a long cut, yes: a 250 Wh station runs a router and ONT for about 14 hours, and it also charges phones and lights. A mini UPS is cheaper, switches over without a blink, and sits permanently behind the router, which makes it the better first buy for short cuts.
Sources: gov.uk: communication providers – ensuring telecom services are resilient, Ofcom: guidance on protecting access to emergency organisations when there is a power cut at the customer's premises (2018), ISPreview: the 2024 electricity costs of big UK ISP home broadband routers (page 2), ISPreview: Ofcom sets guidance to improve resilience of UK broadband and mobile networks (September 2024), ISPreview: broadband ISPs and Ofcom respond to winter blackout fears (2022), ISPreview: Openreach to stop providing battery backup for FTTP broadband (2018), ISPreview: Vodafone, BT, KCOM and Zen Internet prep new UK battery backup (March 2025), ISPreview: BT prep advanced battery backup for UK phone and broadband users (August 2024), ISPreview: BT criticised over failure of broadband battery backup during power cuts (January 2026), ManoMano: mini UPS battery backup 10400mAh 5V/9V/12V/PoE for router and modem (product listing), CNX Software: mini UPS with 5V, 9V, 12V DC and PoE output for routers (2025)
This guide is general information for UK households, not advice for your specific circumstances. In a live emergency follow the instructions of the emergency services, your utility and your council.